Correct selection of microinjectors

Microinjection pump matching
name
feature
Application range
Injection needle
Glass needle
Injection volume
Characteristics
NanoFil
Syringe with minimal dead volume
Small volume injection, such as ophthalmic injection
Yes
No
Minimum dead volume; durable and flexible; a variety of needles available in sizes 26-36G, blunt, pointed or beveled needles; used to move liquid to the glass needle or eliminate air bubbles in the glass needle; can be operated manually or with MMP, DMP, UMP3 are used together.
PV830
Vacuum pneumatic skin lift syringe pump
Intracellular injection of picoliter
NO
YES
Pisheng rose to Nasheng
The injection volume is determined by the inner diameter, pressure and time of the tip. Apply to very small intracellular injections. The glass tip can be as small as 0.1 micron. When the glass tip of one side grips the cell, the other side can be injected.
PV820
Pneumatic skin lift syringe pump
Intracellular injection of picoliter
NO
YES
Pisheng rose to Nasheng
The injection volume is determined by the inner diameter, pressure and time of the tip. Apply to very small intracellular injections. The glass tip can be as small as 0.1 micron.
Nanoliter
Microcomputer controlled piston displacement syringe pump
Oocyte injection
No
Yes
2.3–69 nanoliters (related to the volume that the glass capillary can hold). Multiple hundred samples can be injected quickly and repeatedly.
Highly accurate. A total of 2.3 fluids can be injected between 2.3 and 69 nanoliters (up to 5 microliters with the MICRO4 controller).
UMP3
Automatic syringe pump
For intracranial positioning injection
Yes
Yes
Actually: 5–25 nanoliters (using a 10 microliter syringe)
No pulse transfer liquid; easy to install; well-made and durable, precise parameters
DMP
Digital microscopy manual syringe pump
Manual injection of small amounts of liquid
Yes
Yes
From 10 nanoliters to microliters, depending on the syringe used
Accurate, manual operation.
Can use 100 microliters to 1 ml syringe
Digital rangefinder
MMP
Manual syringe pump with macrometer
Manual injection of small amounts of liquid
Yes
Yes
From 10 nanoliters to microliters, depending on the syringe used
Accurate, manual operation.
Can use 100 microliters to 1 ml syringe
SYS-260
Two-way microelectrophoresis current generator
Injection of dyes, drugs or charged substances from micropipettes
No
Yes
Electronic isolator, battery operated
Glass capillary for submicron tip
No need for a transformer, quietly convert ±9V to ±100V output